search
This product is a non-stock/special order item.
Please call 01752 917447 for more information.

Lutron RA2 In-Line Switch (Black)

  • Model: Lutron RRK-R6ANS-240
  • Power: 220–240 V~ 50/60 Hz
  • Typical Power Consumption: < 0.5 W (Test conditions: Load and LED are off)
  • Regulatory Approvals: CE
  • Dimensions: 46mm width, 153mm length, 32mm height. 
Please Call: 01752 917447
For More Information
100% secure payments

Environment: Ambient operating temperature: 0 °C to 40 °C (32 °F to 104 °F), 0% to 90% humidity, non-condensing. Indoor use only.

Communications: RA2 Select in-line load controls to communicate with the system through Radio Frequency (RF). They must be located within 18 m (60 ft) line-of-sight or 9 m (30 ft) through walls of a Pico wireless control, Radio Power Saver sensor, or RA2 Select repeater. System devices operate at 868 MHz.

ESD Protection: Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.

Surge Protection: Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits.

Power failure memory: should power be interrupted, the control will return to its previously set level prior to the interruption when power is restored.

Mounting: Allow adequate space to ensure convective cooling of load control. Remove any insulation, heat-generating equipment, or obstructions within 120 mm (4.75 in) of the load control. For optimal RF performance, no metal or other electrically conductive material should be present within 120 mm (4.7 in) around the top and sides of the load control. The load control is not suitable for installation in places where it is fully enclosed in metal (e.g., metal enclosures, electrical cabinets) or within metal ceilings.

Wiring: RA2 Select in-line controls that accept wire gauges between 0.5 mm2 to 2.5 mm2 (20 AWG to 14 AWG).

Note: All outside wire diameters must be the same and must be between 5.2 mm–8.5 mm (0.2 in–0.3 in).

Device Limits: Up to 100 devices (e.g., load controls, Pico wireless controls, Radio Powr Savr sensors, shades, and repeaters) are supported per system. The main repeater counts as one device and four locations are reserved for wireless repeaters.

Note: Load controls have load type and capacity limits

Neutral required.

RRK-R6ANS-240